| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. |
| A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access. |
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| immich is a high performance self-hosted photo and video management solution. Prior to 1.132.0, immich is vulnerable to account hijacking through oauth2, because the state parameter is not being checked. The oauth2 state parameter is similar to a csrf token, so when the user starts the login flow this unpredictable token is generated and somehow saved in the browser session and passed to the identity provider, which will return the state parameter when redirecting the user back to immich. Before the user is logged in that parameter needs to be verified to make sure the login was actively initiated by the user in this browser session. On it's own, this wouldn't be too bad, but when immich uses the /user-settings page as a redirect_uri, it will automatically link the accounts if the user was already logged in. This means that if someone has an immich instance with a public oauth provider (like google), an attacker can - for example - embed a hidden iframe in a webpage or even just send the victim a forged oauth login url with a code that logs the victim into the attackers oauth account and redirects back to immich and links the accounts. After this, the attacker can log into the victims account using their own oauth credentials. This vulnerability is fixed in 1.132.0. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| A state machine transition flaw in the Bluetooth Low Energy (BLE) stack of Cypress PSoC4 v3.66 allows attackers to bypass the pairing process and authentication via a crafted pairing_failed packet. |
| An unauthenticated user could discover account credentials via a brute-force attack without rate limiting |
| SEL BIOS packages prior to 1.3.49152.117 or 2.6.49152.98 allow a local attacker to bypass password authentication and change password-protected BIOS settings by importing a BIOS settings file with no password set. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| Pgpool-II provided by PgPool Global Development Group contains an authentication bypass by primary weakness vulnerability. if the vulnerability is exploited, an attacker may be able to log in to the system as an arbitrary user, allowing them to read or tamper with data in the database, and/or disable the database. |
| Yealink RPS before 2025-06-04 lacks SN verification attempt limits, enabling brute-force enumeration (last five digits). |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).
NOTE:
* The vendor believes that this vulnerability only occurs when documented security best practices are not followed. BMC has always strongly recommended to use security best practices such as configuring SSL/TLS between Control-M Server and Agent.
* The vendor notifies that Control-M/Agent is not impacted in Control-M SaaS |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| In One Identity Identity Manager 9.x before 9.3, an insecure direct object reference (IDOR) vulnerability allows privilege escalation. Only On-Premise installations are affected. |
| Reolink Video Doorbell WiFi DB_566128M5MP_W allows root shell access through an unsecured UART/serial console. An attacker with physical access can connect to the exposed interface and execute arbitrary commands with root privileges. NOTE: this is disputed by the Supplier because of "certain restrictions on users privately connecting serial port cables" and because "the root user has a password and it meets the requirements of password security complexity." |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |