Search Results (4799 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42603 2026-04-15 N/A
This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users. Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account.
CVE-2025-42888 2 Microsoft, Sap 4 Windows, Gui, Gui For Windows and 1 more 2026-04-15 5.5 Medium
SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability.
CVE-2025-4394 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2025-47274 2026-04-15 N/A
ToolHive is a utility designed to simplify the deployment and management of Model Context Protocol (MCP) servers. Due to the ordering of code used to start an MCP server container, versions of ToolHive prior to 0.0.33 inadvertently store secrets in the run config files which are used to restart stopped containers. This means that an attacker who has access to the home folder of the user who starts the MCP server can read secrets without needing access to the secrets store itself. This only applies to secrets which were used in containers whose run configs exist at a point in time - other secrets remaining inaccessible. ToolHive 0.0.33 fixes the issue. Some workarounds are available. Stop and delete any running MCP servers, or manually remove any runconfigs from `$HOME/Library/Application Support/toolhive/runconfigs/` (macOS) or `$HOME/.state/toolhive/runconfigs/` (Linux).
CVE-2025-4737 1 Tecno 1 Com.transsion.aivoiceassistant 2026-04-15 6.2 Medium
Insufficient encryption vulnerability in the mobile application (com.transsion.aivoiceassistant) may lead to the risk of sensitive information leakage.
CVE-2025-47419 2026-04-15 N/A
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic. The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
CVE-2025-48428 1 Gallagher 1 Command Centre 2026-04-15 6.7 Medium
Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior.
CVE-2025-48981 1 Compugroup Medical 1 Cgm Medico 2026-04-15 8.6 High
An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection.
CVE-2025-56447 1 Tm2 1 Monitoring 2026-04-15 9.8 Critical
TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure.
CVE-2025-50109 1 Emerson 1 Valvelink 2026-04-15 7.7 High
Emerson ValveLink Products store sensitive information in cleartext within a resource that might be accessible to another control sphere.
CVE-2025-50110 2026-04-15 8.8 High
An issue was discovered in the method push.lite.avtech.com.AvtechLib.GetHttpsResponse in AVTECH EagleEyes Lite 2.0.0, the GetHttpsResponse method transmits sensitive information - including internal server URLs, account IDs, passwords, and device tokens - as plaintext query parameters over HTTPS
CVE-2025-52351 2026-04-15 8.8 High
Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding.
CVE-2025-52579 2026-04-15 9.4 Critical
Emerson ValveLink Products store sensitive information in cleartext in memory. The sensitive memory might be saved to disk, stored in a core dump, or remain uncleared if the product crashes, or if the programmer does not properly clear the memory before freeing it.
CVE-2025-52586 1 Eg4 Electronics 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more 2026-04-15 6.9 Medium
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CVE-2025-61738 1 Johnsoncontrols 5 Iq Panels2, Iq Panels2+, Iqhub and 2 more 2026-04-15 N/A
Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network.
CVE-2025-6180 1 Strongdm 1 Sdm-cli 2026-04-15 N/A
The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition.
CVE-2025-62765 1 General Industrial Controls 1 Lynx+ Gateway 2026-04-15 7.5 High
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
CVE-2025-6748 2026-04-15 2.1 Low
A vulnerability classified as problematic has been found in Bharti Airtel Thanks App 4.105.4 on Android. Affected is an unknown function of the file /Android/data/com.myairtelapp/files/. The manipulation leads to cleartext storage in a file or on disk. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-7396 1 Korenix 1 Jetport 5601v3 2026-04-15 N/A
Missing encryption of sensitive data in Korenix JetPort 5601v3 allows Eavesdropping.This issue affects JetPort 5601v3: through 1.2.
CVE-2025-54818 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8 High
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.