Export limit exceeded: 30000 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2539 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-4425 2026-04-15 5.4 Medium
The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
CVE-2024-51552 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 6 Medium
Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2024-51722 1 Blackberry 1 Secusuite 2026-04-15 6.4 Medium
A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands.
CVE-2024-6834 2026-04-15 9 Critical
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2025-0936 2026-04-15 6.5 Medium
On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc).
CVE-2025-14183 1 Sgai 1 Space1 Nas N1211ds 2026-04-15 4.3 Medium
A vulnerability was found in SGAI Space1 NAS N1211DS up to 1.0.915. This issue affects the function GET_FACTORY_INFO/GET_USER_INFO of the file /cgi-bin/JSONAPI of the component gsaiagent. The manipulation results in unprotected storage of credentials. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14295 2 Automatedlogic, Carrier 2 Webctrl, I-vu 2026-04-15 N/A
Storing Passwords in a Recoverable Format vulnerability in Automated Logic WebCTRL on Windows, Carrier i-Vu on Windows. Storing Passwords in a Recoverable Format vulnerability (CWE-257) in the Web session management component allows an attacker to access stored passwords in a recoverable format which makes them subject to password reuse attacks by malicious users.This issue affects WebCTRL: from 6.0 through 9.0; i-Vu: from 6.0 through 9.0.
CVE-2025-15371 1 Tenda 7 4g03 Pro, 4g05, 4g08 and 4 more 2026-04-15 7.8 High
A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used.
CVE-2025-2342 2026-04-15 5.3 Medium
A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-2343 2026-04-15 7.5 High
A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-24852 2026-04-15 4.6 Medium
Storing passwords in a recoverable format issue exists in CHOCO TEI WATCHER mini (IB-MCT001) all versions. If this issue is exploited, an attacker who can access the microSD card used on the product may obtain the product login password.
CVE-2025-2500 2026-04-15 7.4 High
A vulnerability exists in the SOAP Web services of the Asset Suite versions listed below. If successfully exploited, an attacker could gain unauthorized access to the product and the time window of a possible password attack could be expanded.