| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| D-Link DSL-504T stores usernames and passwords in cleartext in the router configuration file, which allows remote attackers to obtain sensitive information. |
| phpRank 1.8 stores the administrative password in plaintext on the server and in the "ap" cookie, which allows remote attackers to retrieve the administrative password. |
| The web-based Management Console in Blue Coat Security Gateway OS 3.0 through 3.1.3.13 and 3.2.1, when importing a private key, stores the key and its passphrase in plaintext in a log file, which allows attackers to steal digital certificates. |
| IMail stores usernames and passwords in cleartext in a cookie, which allows remote attackers to obtain sensitive information. |
| Capturix ScanShare 1.06 build 50 stores sensitive information such as the password in cleartext in capturixss_cfg.ini, which is readable by local users. |
| Cleartext storage of sensitive information in Azure Compute Gallery allows an authorized attacker to disclose information over a network. |
| OpenClaw before 2026.3.22 contains an information disclosure vulnerability that allows attackers with operator.read scope to expose credentials embedded in channel baseUrl and httpUrl fields. Attackers can access gateway snapshots via config.get and channels.status endpoints to retrieve sensitive authentication information from URL userinfo components. |
| Directus is a real-time API and App dashboard for managing SQL database content. Prior to 11.17.0, Directus stores revision records (in directus_revisions) whenever items are created or updated. Due to the revision snapshot code not consistently calling the prepareDelta sanitization pipeline, sensitive fields (including user tokens, two-factor authentication secrets, external auth identifiers, auth data, stored credentials, and AI provider API keys) could be stored in plaintext within revision records. This vulnerability is fixed in 11.17.0. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct access to the app’s filesystem. |
| A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials. |
| This vulnerability exists in ZKTeco WL20 due to storage of Wi-Fi credentials, configuration data and system data in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the plaintext sensitive data stored in the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized network access, retrieve and manipulate data on the targeted device. |
| This vulnerability exists in ZKTeco WL20 due to storage of admin and user credentials without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted credentials stored in the firmware of targeted device. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information. |
| This vulnerability exists in TP-Link Tapo H200 V1 IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. When a new SD card is inserted into the dashcam, the existing password is written onto the SD card in cleartext automatically. An attacker with temporary access to the dashcam can switch the SD card to steal this password. |