| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A State Pollution vulnerability was discovered in the TON Virtual Machine (TVM) before v2025.04. The issue exists in the RUNVM instruction logic (VmState::run_child_vm), which is responsible for initializing child virtual machines. The operation moves critical resources (specifically libraries and log) from the parent state to a new child state in a non-atomic manner. If an Out-of-Gas (OOG) exception occurs after resources are moved but before the state transition is finalized, the parent VM retains a corrupted state where these resources are emptied/invalid. Because RUNVM supports gas isolation, the parent VM continues execution with this corrupted state, leading to unexpected behavior or denial of service within the contract's context. |
| JSON::XS before version 4.04 for Perl has an integer buffer overflow causing a segfault when parsing crafted JSON, enabling denial-of-service attacks or other unspecified impact |
| Cpanel::JSON::XS before version 4.40 for Perl has an integer buffer overflow causing a segfault when parsing crafted JSON, enabling denial-of-service attacks or other unspecified impact |
| A token is created using the username, current date/time, and a fixed
AES-128 encryption key, which is the same across all installations. |
| Inclusion of undocumented features issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. A remote attacker may disable the LAN-side firewall function of the affected products, and open specific ports. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the network configuration file via a crafted HTTP request. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the wireless network configuration file via a crafted HTTP request. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to delete the configuration of physical network interfaces via a crafted HTTP request. |
| Snowflake PHP PDO Driver is a driver that uses the PHP Data Objects (PDO) extension to connect to the Snowflake database. Snowflake discovered and remediated a vulnerability in the Snowflake PHP PDO Driver where executing unsupported queries like PUT or GET on stages causes a signed-to-unsigned conversion error that crashes the application using the Driver. This vulnerability affects versions 0.2.0 through 3.0.3. Snowflake fixed the issue in version 3.1.0. |
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| SAP Commerce (Backoffice) uses the deprecated X-FRAME-OPTIONS header to protect against clickjacking. While this protection remains effective now, it may not be the case in the future as browsers might discontinue support for this header in favor of the frame-ancestors CSP directive. Hence, clickjacking could become possible then, and lead to exposure and modification of sensitive information. |
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application |
| A stack-based buffer overflow vulnerability exists in the
securebio_identify functionality of Dell ControlVault3 prior to 5.15.10.14 and Dell ControlVault3 Plus prior to 6.2.26.36. A
specially crafted malicious cv_object can lead to a arbitrary code
execution. An attacker can issue an API call to trigger this
vulnerability. |
| Out-of-bounds array write in Xpdf 4.05 and earlier, due to incorrect integer overflow checking in the PostScript function interpreter code. |
| Uptime Kuma >== 1.23.0 has a ReDoS vulnerability, specifically when an administrator creates a notification through the web service. If a string is provided it triggers catastrophic backtracking in the regular expression, leading to a ReDoS attack. |
| A prototype pollution in the lib.set function of dref v0.1.2 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. |
| The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected. |
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
| solid-js is a declarative, efficient, and flexible JavaScript library for building user interfaces. In affected versions Inserts/JSX expressions inside illegal inlined JSX fragments lacked escaping, allowing user input to be rendered as HTML when put directly inside JSX fragments. This issue has been addressed in version 1.9.4 and all users are advised to upgrade. There are no known workarounds for this vulnerability. |
| A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network. |